For Microsoft Windows CE.NETVersion APlease confirm the version of the software built in eClient, and refer to the suited User's Manual (Refer to
Mounting EIZO monitor to the SC1 When using other monitors than EIZO, proceed to step 3. The Monitor Attachment Unit of SC1 supports the EIZO L767, L
(2) Lay the LCD monitor down on the soft cloth or cushion not to scratch the panel surface. (3) Remove the original stand by loosening the screws.
Connecting the signal cable and power cables 3. Plug the signal cable into the connector at the rear of the monitor and the other end of the cable int
NOTE • Bundling cables After all connection has been made, please bundle the cables with the clamp included into the package, so that the cables do
9. The switch box is connected to the attached connector on the SC1 if needed. The secondary power switch makes it easy to turn the SC1 on and off whe
3. SETTING UP the eClient SC1 This chapter presents how to prepare for a connection with a WTS when the eClient SC1 starts up for the first time. 1.
3. End User License Agreement page is displayed. Read the content and click [Accept] to continue. 16 3. SETTING UP the eClient SC1
4. Set up the network environment. [Terminal Name] ...Type the name to identify this unit on the network. Click [Network Properties] a
In case of connecting the WTS/Web through Built-in LAN: (1) Double-click [Built-in LAN] icon. [IP Address] ...Type the IP
In case of connecting with a Cisco wireless LAN card/Agere wireless LAN card: (1) Double-click [CISCO1]/[WLAGS461] icon. [IP Address] ...
User’s Manual Version List A handling description changes with versions of the software built in eClient. Please refer to below. NOTE • The version o
In case of a dial-up connection: (1) Double-click [Make New Connection] icon. (2) Type a name for the connection and select the connection type (Dia
5. Setup the desktop area; resolution, refresh frequency and colors. [Desktop Area, Refresh Frequency and Colors] ...
6. The following page is displayed. Set each icon settings following from step 7 to 9. 7. Set up the browser connection. Set up if you are setting u
8. Set up the printer. Set up if you are using a local printer. NOTE • The following is required to install a local printer. - A printer is connecte
10. The last page of the “eClient Setup Wizard” is displayed. Click [Finish]. Click [Yes] if a “Terminal Settings change” dialog box is displayed. T
4. ADDING & CHANGING A CONNETION NAME This chapter shows how to add, delete, and modify connection names to a WTS. All the settings are managed in
2. Protocol selection dialog box is displayed. Select the “Microsoft Remote Desktop Client” (RDP). 3. “WTS Connection Wizard” is displayed. (Setup as
In Use of the ICA protocol 1. Display [Terminal Connection Manager]. Click the [Configure] tab and [Add...] to set the connection information of the
Clicking [Finish] to return to the “Terminal Connection Manager” dialog box, the registered connection name is displayed in the [Connection Name]. [Ed
5. How to control This chapter shows how to log on to and log off from a WTS. 5-1. Logging on or off the WTS Logging on to the WTS 1. Turn on the S
SAFETY SYMBOLS This manual uses the safety symbols below. They denote critical information. Please read them carefully. WARNING Failure to abide b
4. The SC1 connects to the WTS and the “Log On to Windows” dialog box is displayed. Enter your [User name] and [Password], and then click [OK] to
Logging off the WTS If your SC1 starts its operation with a desktop: 1. Log off the WTS. (1) Close all the applications. (2) Select [Start] on the
If your SC1 starts its operation with an application: 1. Log off the WTS. Close the applications to log off from the WTS. The “Terminal Connection
Opening/Closing the Local Web Browser Opening the Local Web Browser 1. Turn on the SC1. 2. The “Terminal Connection Manager” dialog box will be displa
Closing the Local Web Browser (SC1) 1. Close the local web browser. Select [Close] on the [File] and close the local web browser. The “Terminal Conne
6. USING THE TERMINAL PROPERTIES This chapter presents how to modify all settings of the eClient SC1 using the “Terminal Properties”. To display the “
Software Windows CE Version, Terminal server Client version/build, Boot software version/build, Update Hardware Serial Number System Network Networ
6-2. Display Resolutions / Desktop Colors [Desktop Area, Refresh Frequency and Colors] ...Set the resolution,
Screen Saver [Enable Screen Saver]...Set the screen saver. Select the check box, and set an idle period into the [Wait] box. [Turn off monitor
Dialing [Location name]...Choose the sender’s location (click [New] to add a new sender’s location). [Local Settings are:] ...
TABLE OF CONTENTS 1. INTRODUCTION ... 5 1-1. General Description ...
Password [Password] ...This enables password settings on FTP service (p.47) and Security functions (p.48). Mouse [Bu
Date / Time NOTE • Date and time will return to the default settings if the power cord is unplugged. [Date/Time] ...Set dat
Certificates Lists the certificates stored in the SC1. A certificate can be registered, if an external disk is connected to this product, a certi
Add-on Add-on lists all application software installed in eClient. To remove software, select it and click [Remove]. NOTE • Neither Microsoft Ter
Printers NOTE • The eClient SC1 supports an LPTx port and a COM1 port. • Use a RDP protocol to set the printer’s adjustment. • If you are usi
Network and Dial-up Connections Set up connection information according to the connection method to WTS/Web server (See page 18 for the details).
6-6. ICA Settings (ICA Protocol only) NOTE • The settings will affect all the settings with ICA protocol. ICA Client information [ICA Client Softwa
6-7. Server FTP Service NOTE • Before setting the FTP service, specify the [Password] in the [Control Panel] tab surely. [FTP Service]...
6-8. Security Security Settings [Terminal Security Enable] ...This enables settings on network information of the W
[Single Button Connect Enable] ...(Select the [Terminal Security Enable] check box to enable this check box.) The pro
1. INTRODUCTION Thank you very much for purchasing the EIZO eClient SC1. 1-1. General Description The SC1 is used as a thin client, which connects to
6-9. System Product Information [Software] ...Microsoft Windows CE Version, Revision Window Terminal Server Client Revision (
7. SOFTWARE UPDATING/INSTALLATION You can update the built-in/add-on software and install new add-on software. Updating/Installation is performed in
2. “Software Update” dialog box is displayed. [Server:] ...Type IP address or full domain name of the FTP Server. [User
3. Preventing from update failure, check if the settings are correct and the network environment is suitable. Click [Network Test]. If the settings
Using the SC1 as a FTP server The firmware file can be updated by the SC1 set as a FTP server when two or more SC1 exists on the same network NOTE •
8. PRACTICAL SETUP 8-1. SC1 settings By utilizing the DHCP Option function of the DHCP Server, necessary information are supplied by the DHCP Server,
NOTE • Making a Registry File to Connect to a WTS/Web Server. • Please refer to the example below, make a registry file, and save it in Unicode for
eClient SC1 Settings Please confirm the following settings in the [Control Panel] tab of [Terminal Properties]. [Network and Dial-up Connections] tab
8-2. Short cut command by keyboard Function Short cut command Display “Terminal Connection Manager” dialog box (after WTS / Web connection) Press [Ct
9. TROUBLESHOOTING This page presents problem that can be corrected by the user. If a problem persists even after applying the suggested remedies, co
• Secondary power switch (wired) 1-3. Package Contents Please contact your local dealer for assistance if any of the listed items are missing or d
10. CLEANING Periodic cleaning is recommended to keep the monitor looking new and to prolong its operation lifetime. NOTE • Never use thinner, benz
11. SPECIFICATIONSCPU VIA Eden, 800 MHz CPU and Memory Memory RAM: 128 MB, ROM: 32 MB Display Color 256 / 65536 / 16 M colors Supported Resolution
Dimensions (eClient only) mm (inches) 200(7.9)63(2.48)5(0.2)55(2.17)60214(8.4) 22(0.87)295(11.6)178(7.0)89(3.5)156(6.1)166(6.5)27(1.06)12(0.47)AC INP
L557/L567 L767 11. SPECIFICATIONS 63
1-4. Controllers & Connectors Controllers AC INPUTAC OUTPUTPower SYNCOFFON(1)(2)(3)(4)(5) (1) Power Button (2) Power Indicator Power Indicator
Connectors AC INPUTAC INPUTAC OUTPUTAC OUTPUTPower SYNCPower SYNCOFFOFFONON(3)(2)(1)(8)(9)(11)(10)(6)(5)(4)(12)(7) (1) Power Supply Control Swit
2. CONNECTING the eClient SC1 This chapter explains how to connect the eClient SC1 to a WTS. 2-1. Setting up the eClient SC1 Please observe the follo
Commentaires sur ces manuels