Chapter4SelfCalibration
Setting calibration schedule
Set the calibration schedule for SelfCalibration.
Attention
Clock adjustment is necessary for SelfCalibration to operate.
Procedure
1. Choose “SelfCalibration” from the Adjustment menu, and press
.
2. Choose “Settings” from “SelfCalibration”, and press
.
3. Choose “Schedule” from “Settings”, and press
.
The schedule setting menu appears.
4. Use or to select the items to change, and press .
Settings Setting
StartingTime Off SelfCalibrationisnotexecuted. Setthetimingatwhich
SelfCalibrationisexecuted.
PowerSave Tobeexecutedunderanyofthe
followingconditions.
• Themonitorisinthepower
savingmodeorthepower
isturnedoffwhenthetime
periodsetinthescheduleis
reached(“Type-1”or“Type-
2”).
• Themonitorshiftstothe
powersavingmodeorthe
poweristurnedoffwhen
thetimeperiodsetinthe
schedulehaselapsed.
Immediately Whenthetimeperiodsetin
theschedulehaselapsed,itis
executedimmediately.
SettingType
*1
Type1 inmonths Setaccordingtothefrequencyat
whichSelfCalibrationisexecuted.
Type2 inweeks
Type3 inhours(monitorusagetime)
Interval Type1 1-12months Settheintervalbetweenthe
completedSelfCalibrationandthe
nextexecution.Thesettingdetails
differdependingonthetypeof
“SettingType”specied.
Type2 1-5weeks
Type3 50-500hours
Week(s) 1stweek-5thweek Setwhichweektoexecute
SelfCalibrationonforthemonthin
whichcalibrationisexecuted.
Day SUN/MON/TUE/WED/THU/FRI/SAT Setwhichdaytoexecute
SelfCalibrationonfortheweekin
whichcalibrationisexecuted.
Time 00:00-23:30 SetthetimeatwhichSelfCalibration
isexecuted.
*1 Settings that are used frequently can be preset.
5. Use or for adjustment.
6. Press
to exit.
The calibration schedule is set.
Note
When the starting time is “Immediately”, and the setting type is either “Type1” or “Type2”, SelfCalibration is
executed according to schedule even if the power is switched off using
.
When the starting time is “Off, the SelfCalibration menu shows “Setting incomplete.” However, SelfCalibration can
be executed manually.